SPECIFICATIONS for PJ Bench & Portable Models (6KV - 20KV) |
MODEL NUMBER* |
PEAK VOLTAGE
OUTPUT Rise Time = 0.1
µsec |
POWER INPUT* (Volt Amps) |
PEAK CURRENT
OUTPUT |
DIMENSIONS L" x W" x H"
|
APPROX. WEIGHT |
H6
S6 TS6 TSM6 SP6 SPM6 MB6 M6 |
6,000
v 6,000 v 6,000 v 6,000 v 6,000 v 6,000 v 6,000 v
6,000 v |
360 VA
360 VA 360 VA 360 VA 360 VA 360 VA 360 VA 360 VA |
150
amps 150 amps 150 amps 150 amps 150 amps 150 amps 150
amps 150 amps |
22" x 19" x 5.5" 18.5" x 19" x
12.5" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x
19" x 14.0" 18.5" x 19" x 10.7" |
42 lbs 61
lbs 65 lbs 63 lbs 63 lbs 61 lbs 67 lbs 66
lbs |
|
|
H10
S10 TS10 TSM10 SP10 SPM10 MB10 M10
|
10,000
v 10,000 v 10,000 v 10,000 v 10,000 v 10,000 v 10,000 v 10,000 v |
720 VA 720 VA 720 VA 720 VA 720 VA 720 VA 720 VA 720 VA |
300
amps 300 amps 300 amps 300 amps 300 amps 300 amps 300
amps 300 amps |
22" x 19" x 5.5" 18.5" x 19" x
12.5" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x
19" x 14.0" 18.5" x 19" x 10.7" |
44 lbs 63
lbs 67 lbs 64 lbs 65 lbs 62 lbs 69 lbs 67
lbs |
|
|
H12
S12 TS12 TSM12 SP12 SPM12 MB12 M12 |
12,000
v 12,000 v 12,000 v 12,000 v 12,000 v 12,000 v 12,000 v 12,000 v |
840 VA 840 VA 840 VA 840 VA 840 VA 840 VA 840 VA 840 VA |
375
amps 375 amps 375 amps 375 amps 375 amps 375 amps 375
amps 375 amps |
22" x 19" x 5.5" 18.5" x 19" x
12.5" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x
19" x 14.0" 18.5" x 19" x 10.7" |
46 lbs 65
lbs 69 lbs 65 lbs 67 lbs 63 lbs 71 lbs 68
lbs |
|
|
H15
S15 TS15 TSM15 SP15 SPM15 MB15 M15
|
15,000
v 15,000 v 15,000 v 15,000 v 15,000 v 15,000 v 15,000 v 15,000 v |
1080 VA 1080 VA 1080 VA 1080 VA 1080 VA 1080 VA 1080 VA 1080 VA |
500
amps 500 amps 500 amps 500 amps 500 amps 500 amps 500
amps 500 amps |
22" x 19" x 5.5" 18.5" x 19" x
12.5" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x 19" x 14.0" 18.5" x 19" x 10.7" 18.5" x
19" x 14.0" 18.5" x 19" x 10.7" |
48 lbs 67
lbs 71 lbs 66 lbs 69 lbs 64 lbs 73 lbs 69
lbs |
|
|
S20 SP20
|
New! 20,000
v New! 20,000 v |
1440 VA 1440 VA |
700
amps 700 amps |
18.5" x 19" x 14.0" 18.5" x 19" x 14.0" |
73 lbs 95 lbs |
|
SPECIFICATIONS for PJ Console Models (10KV - 60KV) |
MODEL NUMBER* |
PEAK VOLTAGE
OUTPUT Rise Time = 0.1
µsec |
POWER INPUT* (Volt Amps) |
PEAK CURRENT
OUTPUT |
DIMENSIONS L" x W" x H" |
APPROX. WEIGHT |
C10
TC10 HC10 MC10 |
10,000 v |
720 VA |
300 amps |
22" x 21" x 49"
|
  285 lbs
|
C12
TC12 HC12 MC12 |
12,000 v |
840 VA |
375 amps |
22" x 21" x 49"
|
  290 lbs
|
C15
TC15 HC15 MC15 |
15,000 v |
1080 VA |
500 amps |
22" x 21" x 49"
|
  295 lbs
|
C20
TC20 HC20 MC20 |
20,000 V |
1440 VA |
700 amps |
22" x 21" x 49"
|
  305 lbs
|
C25
TC25 HC25 MC25 |
25,000 v |
1800 VA |
800 amps |
22" x 21" x 49"
|
  345 lbs
|
C30
TC30 HC30 MC30 |
30,000 v |
2160 VA |
900 amps |
22" x 21" x 49"
|
  360 lbs
|
| C35
|
35,000
v |
2400 VA |
1050
amps |
22" x 21" x 49"
|
380
lbs |
| HC35
|
35,000
v |
2400 VA |
1050
amps |
25" x 21" x
56" |
390
lbs |
| C40
|
40,000
v |
2640 VA |
1200
amps |
22" x 21" x 49"
|
395
lbs |
| HC40
|
40,000
v |
2640 VA |
1200
amps |
25" x 21" x
56" |
405
lbs |
| C50-2M*
|
50,000
v |
3000 VA |
1600
amps |
22" x 21" x 49"
|
410 lbs |
| HC50-2M*
|
50,000
v |
3000 VA |
1600
amps |
25" x 21" x
56" |
425 lbs |
| C60-2M*
|
New! 60,000
v |
3600 VA |
2000
amps |
25" x 21" x
56" |
415 lbs |
|
|
DC HI-POT
SPECIFICATIONS |
MODEL NUMBER |
MAXIMUM
OUTPUT VOLTAGE |
MAXIMUM
OUTPUT CURRENT |
HI-POT OVERCURRENT
TRIP |
CURRENT RESOLUTION |
| SP6, SPM6, MB6,
M6 |
6
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| SP10, SPM10, MB10,
M10, HC10, MC10 |
10
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| SP12, SPM12, MB12,
M12, HC12, MC12 |
12
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| SP15, SPM15, MB15,
M15, HC15, MC15 |
15
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| SP20,HC20, MC20 |
20
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| HC25, MC25 |
25
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| HC30, MC30 |
30
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| HC35 |
35
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| HC40 |
40
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
| HC50-2M* |
50
KV |
2000 µ amps |
2000 µ amps |
0.1 / 1 micro amps |
|
|
| SPECIAL FEATURES |
 |
All testers meet IEEE
standard 522-1992 for voltage rise time (0.1
µsec.) |
 |
Factory Calibration on all
P J Surge Testers is traceable to N I S T |
 |
Removable Tektronix or Rigol Digital Storage Oscilloscope** with Software and a USB Flash Drive - Tektronix serviceable world-wide |
 |
All consoles constructed in steel cabinets equipped with 6" heavy duty rubber wheels and supplied with a power receptacle for accessories |
 |
Modularized for simplified
maintenance |
 |
Ergonomically designed for
operator efficiency |
 |
Easily operated by
non-technical personnel |
 |
All internal components
are conservatively rated with large margins of safety to ensure
trouble free performance |
|
| *All testers are designed to operate at 120 volts AC, single
phase, 50/60 Hz (except 50KV & 60KV models). 220-240 operating line voltage is available upon request and for an additional cost. Please add the following designation, "-2M", after the model number for PJ Surge Testers designed to operate from 220-240 operating line voltage. *50KV & 60KV models (C50, HC50 and C60) only available in 220-240VAC. Therefore, the C50, HC50 and C60 models are identified as Model C50-2M, Model HC50-2M and Model C60-2M, respectively. TOP |
|
| **Fully Digital storage oscilloscope can be used for
trouble shooting motor controllers, power supplies, printed circuit
boards and other electronic circuitry. (Optional probe required.)
TOP |
|
|
|
| OPERATOR SAFETY
FEATURES |
|
| P J SURGE
TESTERS are designed with the safety of the operator in mind. The
special features listed below are standard on all
models: |
|

TOP |
• Grounded Three Prong AC
line cord • Bleeder Resistors • Power Receptacle to accommodate warning lights • Foot Switch • Tester
Ground Safety Indicator (For 120VAC operation only) • Safety
Light Interlocks • Double Pole "ON-OFF" Switch • Hi-Pot Grounding Rod (Console Hi-Pot Models only) • High Voltage Grounding Rod (Model C60-2M only)
|
|
|
|
|
|
HOME | WHY BUY A PJ SURGE TESTER | MODELS AVAILABLE | SPECIFICATIONS | PRICE LIST | CONTACT US | TECHNICAL SUPPORT | WHAT'S NEW
|
|
Click here for a PDF printable version of this page.
Please note: BabelFish Translation is not a "technical" web site. Therefore, some words may not translate correctly. We apologize if your particular country is not listed.
 |
www.pjsurgetesters.com or www.pjelectronics.com
© PJ Electronics Inc. 1999-2010 All rights reserved worldwide
575 Davidson Road | Pittsburgh, PA 15239 USA
Phone/Fax: 001 412-793-3912
Toll Free Phone: 1-877-475-8378 (1-877-4PJ TEST)
EMAIL:sales@pjsurgetesters.com
|
| | |